The RED TEK 22a A/C Recharge Kit is designed as a DIY direct replacement refrigerant option for replacing R22 in residential and commercial air conditioning and refrigeration systems. RED TEK 22a Recharge Kit includes everything required to recharge your A/C system.

  • Designed as a direct replacement for R22 refrigerant

  • Installation hose kit with colour coded gauges

  • 3 cans of RED TEK 22a A/C Refrigerant (8 oz cans), 1 RED TEK 22a Recharge Gauge Kit & 1 RED TEK R22 Oil Analyzer

  • A cost effective and efficient option for retrofit/replacement option for home and commercial air conditioning systems

  • NOTE: Environmental regulations require the home air conditioning system be empty of, or properly evacuated of, R22 refrigerant by certified personnel prior to charging the system with alternative products.

Part Number 350
Battery Platform None
Colour Not Applicable
Package Depth (cm) 20.95 cm
Package Depth (in) 8.25 in
Package Height (cm) 19.68 cm
Package Height (in) 7.75 in
Package Weight (kg) 1.36 kg
Package Weight (lb) 3.00 lb
Package Width (cm) 11.43 cm
Package Width (in) 4.50 in
Product Height (cm) 19.68 cm
Product Height (in) 7.75 in
Product Length (cm) 20.95 cm
Product Length (ft) 0.69 ft
Product Volume (L) 0.72 l
Product Volume (gal) 0.19 gal (US)
Product Weight (g) 9530.00 g
Product Weight (kg) 9.53 kg
Product Weight (lb) 21.01 lb
Product Width (cm) 11.43 cm
Product Width (in) 4.50 in

Our return policy

View full return policy

Warranty

This product carries a special warranty. Please see your local Canadian Tire store for details.

Compare Similar Products

Only Show Differences
Ratings
Battery PlatformNoneNoneNoneNone
ColourNot ApplicableNot ApplicableNot ApplicableNot Applicable
Package Depth (cm)11.43 cm6.69 cm11.43 cm12.30 cm

Weekly Deals

Review Highlights

List of Pros Highlights
List of Cons Highlights

Reviews

Rating Snapshot

Select a row below to filter reviews.
28 reviews with 5 stars.
8 reviews with 4 stars.
1 review with 3 stars.
2 reviews with 2 stars.
11 reviews with 1 star.

Overall Rating

3.8
22 out of 34 (65%) reviewers recommend this product

Review this product

Select to rate the item with 1 star. This action will open submission form.
Select to rate the item with 2 stars. This action will open submission form.
Select to rate the item with 3 stars. This action will open submission form.
Select to rate the item with 4 stars. This action will open submission form.
Select to rate the item with 5 stars. This action will open submission form.
Adding a review will require a valid email for verification

Customer Images and Videos

Filter Reviews

  • purchase
  • ease of use
  • price
  • for emergencies
  • instructions
  • large
  • quality
  • satisfaction
1 to 5 of 50 Reviews
1 – 5 of 50 Reviews

GREAT DEAL, BUY THIS!

a month ago
Great kit, easy to use and air conditioning is blowing cold again.
Helpful?

Not For Automotive Use, Sold In The Automotive Section

2 months ago
Bought this kit, from the automotive section of my store, got it home, and the hose had the wrong connector. While looking through the box in hopes of finding an adapter, I noticed the words NOT FOR AUTOMOTIVE USE printed on the cans and the box… Returned, and refunded. Shame on me for not reading the label, shame on Canadian Tire for selling this in the automotive section.

No, I do not recommend this product.

Helpful?

Excellent product

3 months ago
My SUV's AC stopped working and my garage filled up the refrige. About a week later on a Friday the AC wasn't working again. Of course all of the the garages were closed and it was Louisiana kind of hot out. A wonderful employee innthe automotive section made sure I picked up the correct items and I was out and refilling the refrigerant within 15 minutes
Helpful?

Full kit for refill older models of AC.

3 months ago
It is almost full kit for add or change refrigerant in older models AC. Missing only oil. I've bought it in addition. It works well, except oil tester. My was not working. I've used only half of 1 bottle of 3. And I will keep the rest for next time.
Helpful?

Poor meter

3 months ago
the meter is not working but it can't be returned
Helpful?
1 – 5 of 50 Reviews

Questions

1 - 8 of 8 Questions

Q: Has anyone had good results with the product?

13 years ago
4 Answers
  • A: Yes , after several professionals could not find the problem I bought some dye online and found a small leak near a sensor , bought the r 22 and some pro seal . put in 8 cans of gas and 2 cans of pro seal , that was 5 years ago. and system is like new.

    3 years ago
    Helpful?

Q: I have the R22 gas filled in my house air conditioner. I will like to ask you that if I buy this product I can just fill it up or do I have to empty t I will like to ask you that if I buy this product I can just fill it up or do I have to empty the air condition meaning vaccum it and then afterwards fill the gas.

15 years ago
4 Answers
  • A: I have r22 also and topped it up with leakstop22 and red tek22a, you do not have to empty it, i googled this info and it worked well for me.

    12 years ago
    Helpful?

Q: Where to connect the rechargable set to prevent mentioned problems? See picture. I think the problems mentioned are related with the connection of the rechargable set. Can somebody show in the picture wich one is the LOW pressure connection to attach the REDTEK connector? The 2 connectors (LOW & HIGH) in the AC unit are similar.

13 years ago
3 Answers
  • A: connect charging hose to low pressure line, the one that is bigger and insulated

    12 years ago
    Helpful?

Q: No instruction for guage. Do I use outer most Blue numbers? What is the inner most R22 green numbers for?

2 years ago
2 Answers
  • A: Use the blue scale second row of numbers in. The max pressure with the compressor running should not exceed 70 psi or the system may ice up when hooked up to the low pressure cold line. The other line may run up to 300 psi but you should nor test it with this gauge. The high oressure line will be warm to hot to the touch when the compressor is running.

    2 years ago
    Helpful?

Q: how long does it take to refill the r22 into the a/c? it takes minutes like 5-15 or it takes longer from 1 hour to several hours for the entire can to be pulled into the a/c?

13 years ago
2 Answers
  • A: it took about 2 minutes for most of the can to flow into running compressor, i noticed that there was a little bit left in can after i removed, but no big deal.

    12 years ago
    Helpful?

Q: I have an r22 system, I am trying to add up with 22a Freon , when I look the gauge do I have to watch for the PSI or what. Thanks

6 years ago
1 Answer
  • A: When adding R22a, the low side pressure should be checked with the A/C unit running and should be somewhere between 67-75 psi.

    6 years ago
    Helpful?

Q: My system is 20 yeas old. Will the hose hook right up or will I need adapters?

9 years ago
1 Answer
  • A: More information is needed. Please call 1-888-676-9380 for technical support.

    9 years ago
    Helpful?

Q: Équivalent au R410? et en vente libre? Est-ce que ce produit ce vend en vente libre ou bien si un permi est nécessaire? Est-ce que ce produit est une équivalence au R410? Combien de bar ces cannettes peuvent atteindre?

14 years ago
Translate with Google
1 Answer
  • A: Vous n'avez pas besoin d'un permis pour l'achat. Cependant, votre système doit être évacué du réfrigérant par un professionnel, et les fuites doivent être réparées avant la charge avec le 22a.

    12 years ago